Industrial Boilers MECHEL Târgovişte

RAB Steam Boiler

 

Technical data:

– Rated steam pressure: 8 bar;
– Max. pressure of steam in drum: 9 bar;
– Saturated steam temperature: 160°C;
– Nominal flow rate of steam: 10 t/h;
– Nominal diameter of the steam pipe: DN150
– flue gas temperature at entry in vaporizer: 550°C;
– flue gas temperature at exit from economizer: 200°C;
– Nominal flow rate of water supply: 12 t/h;
– Maximum rate of water supply: 16 t / h;
– Feed water temperature: 104°C;
– Nominal diameter of pipe water supply: DN 65;
– Continuous control of water level in the vaporizer;
– pressure of instrumental air (nitrogen): 4 … 5 bar.

ABA Steam Boiler

 

Boiler produces saturated steam with the following parameters:

– Nominal steam flow rate: 8 t/h
– Minimum flow steam 2.4 t / h
– Nominal pressure of steam: 20 bar
– Pressure steam for activation the safety valves: 21.75 bar
– Pressure steam for activation the protection (fire extinction): 21.5 bar
– The nature of saturated steam
– Water: 2 centrifugal pumps (working + backup)
– Debit / pump: 15 m3/h
– Pressure: 25 bar
– Power motor: 37 kW/380V c.a.
– Water supply temperature (from getter) 40-104oC
– Diameter of water pipe: Dn 65

PENTAX Image